Phoenix 12/250 VE.Direct Schuko

Details:

The VICTRON Phoenix 12V / 250VA inverter with VE.Direct connection and Schuko socket on the front, offers a pure sine wave, high peak power, integrated low voltage protection. It also has VE.Direct connectivity for setting and control. If you are looking for a reliable and efficient inverter for your low consumption devices, the VICTRON Phoenix 12V / 250VA is an excellent option.

Weight

2 , 4 kg

Dimensions

86 × 165 × 26 cm

Brands

Victron

Voltage

12V

Description

Technical characteristics:

                                                                                                  PHOENIX CONVERTER 12V / 250VA
Continuous power at 25°C  250 VA
Continuous power at 25°C / 40°C  200 / 150 W
Peak power  350 W
AC output frequency / voltage (adjustable) 230 Vac +/- 3% – 50 Hz or 60 Hz +/- 1%
Supply voltage range 9.2 to 17 V
Low DC voltage shutdown (adjustable) 9.3 V
Low DC voltage alarm and restart (adjustable) 10.9 V
Charged battery detection (adjustable) 14 V
Yield 87 %
No-load consumption 4.2 W
No-load consumption in ECO mode with 2.5s interval (adjustable) 0.8 W
ECO mode start and stop setting adjustable
Protections short circuit, overload, high and low battery voltage, high temperature, high DC ripple
Temperature range -40°C to +60°C (fan cooling) reduction 3% per °C above 40°C
Humidity (non-condensing) 95% max
                                                                                                                              HOUSING
Materials and color Steel frame and blue plastic casing RAL 5012
Battery connection Screw terminals
Max cable section 10 mm²
Standard AC outlets Schuko (CEE 7/4), IEC-320 (male plug included)

UK (BS 1363), AU/NZ (AS/NZS 3112)

Protection index IP21
Weight 2.4 kg
Dimensions (H x W x D) 86 x 165 x 260 mm
                                                                                                                      ACCESSORIES
Remote on/off switch Yes
Automatic transfer switch Filax
                                                                                                                          STANDARDS
Security EN/IEC60335-1 EN/IEC62109-1
EMC EN55014-1 EN55014-2 IEC61000-6-1 IEC61000-6-3
Automotive Directive 2004/104/EC EN50498

VE.Direct communication port

The VE.Direct port can be connected to:

  • A computer with the VE.Direct > USB interface cable (RG1060277)
  • Apple and Android smartphones, tablets, Macbooks and other devices with the Bluetooth Smart dongle (RG1060280)

Fully configurable:

  • Reset levels and alarm triggering in case of low battery voltage
  • Low Battery Voltage Restart and Shutdown Levels
  • Output voltage from 210V to 245V
  • Output frequency 50Hz or 60 Hz
  • ECO mode detection level and ECO mode on/off

Monitoring :

  • Current and voltage alarms, input and output